Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev. lasallista investig ; 19(1): 265-284, ene.-jun. 2022. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1423986

RESUMO

Resumen Los polímeros termoplásticos, pueden ser mezclados con diferentes tipos de cargas con el propósito de mejorar su rendimiento físico-mecánico, al mismo tiempo que permiten en muchos casos, generar soluciones a problemáticas ambientales como por ejemplo la disposición final de residuos de madera. Los compuestos de madera plástica son productos elaborados mediante la incorporación de fibras o partículas de madera en la matriz polimérica, donde la interacción entre los dos materiales (nula o con acople) es clave para lograr un adecuado desempeño del producto final. En esta revisión se establecen las matrices poliméricas y los tipos de maderas empleadas comúnmente en la elaboración de productos de madera plástica, al mismo tiempo que se definen los tratamientos previos que deben ser realizados tanto en la madera como en el polímero con el propósito de mejorar la compatibilidad de los dos materiales, y de esta manera mejorar propiedades como la absorción de agua, la resistencia a la descomposición, a la intemperie y el desempeño mecánico. En cuanto a las propiedades mecánicas, al adicionar un contenido de madera en el polímero se modifica la rigidez del material polimérico y la resistencia en tensión, flexión e impacto; sin embargo, se establece que es clave el uso de agentes funcionalizantes para que el efecto de la incorporación de la madera en polímero sea positivo. Finalmente se estudian las nuevas tendencias en el uso de diferentes tipos de residuos y matrices poliméricas para la elaboración de maderas plásticas.


Abstract Polymeric materials, especially thermoplastics, can be mixed with different types of fillers to improve their physical-mechanical performance, at the same time they allow, in many cases, to generate solutions to environmental problems such as the final disposal of wood waste. The plastic wood composites are products made by incorporating wood fibers in the polymer matrix, where the interaction between the two materials is key to achieve an adequate performance of the final product. This review establishes the polymer matrices and the types of wood commonly used in the production of plastic wood products, at the same time defining the previous treatments that must be carried out in the wood and in the polymer to improve the compatibility of the two materials, and in this way improve properties such as water absorption, resistance to decomposition, resistance to weathering and mechanical performance. Related to the mechanical properties, adding the wood fibers in the polymer modifies the rigidity of the polymeric material and the resistance in tension, bending and impact; however, it is established that the use of functionalizing agents is a fundamental key to improve the effect of wood incorporation into the polymer matrix. Finally, the new trends in the use of different types of waste and polymeric matrices to produce plastic wood are studied.


Resumo Os materiais poliméricos, principalmente os termoplásticos, podem ser misturados a diferentes tipos de cargas para melhorar seu desempenho físico-mecânico, ao mesmo tempo que, em muitos casos, permitem gerar soluções para problemas ambientais como a destinação final de resíduos. madeira. Os compósitos madeira-plástico são produtos obtidos pela incorporação de fibras de madeira à matriz polimérica, onde a interação entre os dois materiais é fundamental para um desempenho adequado do produto final. Nesta revisão, são estabelecidas as matrizes poliméricas e os tipos de madeira comumente utilizados na produção de produtos plásticos de madeira, ao mesmo tempo em que são definidos os tratamentos anteriores que devem ser realizados na madeira e no polímero para melhorar a compatibilidade dos dois materiais, e desta forma melhorar propriedades como absorção de água, resistência à decomposição, intempéries e desempenho mecânico. Em relação às propriedades mecânicas, ao adicionar as fibras de madeira ao polímero, a rigidez do material polimérico e a resistência à tração, flexão e impacto são modificadas; porém, está estabelecido que o uso de agentes funcionalizantes é fundamental para que o efeito da incorporação da madeira no polímero seja positivo. Por fim, são estudadas as novas tendências no uso de diferentes tipos de resíduos e matrizes poliméricas para a produção de madeira plástica.

2.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385745

RESUMO

ABSTRACT: The glass ionomer cements (GICs) is a generic name given to a group of materials widely used in clinical dentistry which if used after the specified expiration date, material properties may be affected. to evaluate the Vick ers microhardness, surface morphology and the energy dispersive X-ray microanalysis (EDX), of GICs with different expiration dates that were stored at room temperature. specimens of highly viscous glass ionomer cement (HVGIC) (Ketac Cem and Ketac Molar) and resin-modified glass ionomer cement (RMGIC) (Vitrebond) with different expiration dates (current, close to their expiration and expired) were prepared for Vickers microhardness test and scanning electronic microscopy (SEM) with EDX, measuring 5 mm in diameter and 2 mm length, per the manufacturer's instructions, in standard cylindrical teflon molds. For the comparison of obtained values, the ANOVA test was used, while Tukey test was used for the multiple comparisons. In all the GICs used, the microhardness decreased as the expiration date approached, finding a significant statistical differen ce (P<0.05) in Ketac Molar and Vitrebond. SEM sample analysis revealed similar cohesive cracks in all tested materials. The EDX analysis revealed the presence of the elements F, Al and Si in all GICs and Ca only in Ketac Molar and Ketac Cem. The elements were found in a higher atomic percentage in the GICs with an current date and in a lower percentage in those with an expired date. HVGIC and RMGIC with an expiration date finish and that were stored at room temperature, suffer significant physical and chemical changes, which could put doubts its clinical effectiveness.


RESUMEN: El cemento de ionómero de vidrio (CIV) es un nombre genérico que se le da a un grupo de materiales ampliamente utilizados en odontología clínica que si se usan después de la fecha de vencimiento especificada, las propiedades del material pueden verse afectadas. evaluar la microdureza Vickers, la morfología superficial y el microanálisis de energía dispersa de rayos X (EDX), de CIV con diferentes fechas de caducidad almacenados a temperatura ambiente. Muestras de cemento de ionómero de vidrio de alta viscosidad (CIVAV) (Ketac Cem y Ketac Molar) y cemento de ionómero de vidrio modificado con resina (CIVMR) (Vitrebond) con diferentes fechas de vencimiento (vigente, próximo a su vencimiento y vencido) de 5 x 2 mm, fueron preparadas para microscopía electrónica de barrido (MEB) con EDX y microdureza Vickers, según las instrucciones del fabricante, en moldes de teflón cilíndricos estándar. Para la comparación de los valores obtenidos se utilizó la prueba ANOVA, mientras que para las comparaciones múltiples se utilizó la prueba de Tukey. En todos los CIV utilizados, la microdureza disminuyó a medida que se acercaba la fecha de vencimiento, encontrándose una diferencia estadística significativa (P <0.05) en Ketac Molar y Vitrebond. El análisis de la muestra en MEB reveló grietas cohesivas similares en todos los materiales probados. El análisis EDX reveló la presencia de los elementos F, Al y Si en todos los GIC y Ca solo en Ketac Molar y Ketac Cem. Los elementos se encontraron en mayor porcentaje atómico en los GIC con fecha vigente y en menor porcentaje en aquellos con una fecha vencida. Los CIVAV y CIVMR con fecha de caducidad vencida y que fueron alma- cenados a temperatura ambiente, sufrieron cambios físicos y químicos importantes, lo que podría poner en duda su efectividad clínica.

3.
J. oral res. (Impresa) ; 10(2): 1-9, abr. 30, 2021. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1381731

RESUMO

Objective: To determine the cytotoxicity and effects of graphene oxide (GO) on cellular proliferation of gingival-fibroblasts, pulp-dental cells and human osteoblasts in culture, and to determine the physical, mechanical and biological properties of poly (methyl methacrylate) (PMMA) enriched with GO. Material and Methods: The GO was characterized with SEM. Cytotoxicity and cell proliferation were determined by the MTT bioassay. The physical mechanical tests (flexural strength and elastic modulus) were carried out with a universal testing machine. Sorption and solubility were determined by weighing before and after drying and immersion in water. Porosity was evaluated by visual inspection. Data were analyzed with Student's t-test and Tukey's posthoc ANOVA. Results: The GO has a heterogeneous morphology and a particle size of 66.67±64.76 µm. GO has a slight to no-cytotoxicity (>50-75% viability) at 1-30 days, and at 24 hours incubation of PMMA with GO significantly stimulates osteoblasts (45±8%, p<0.01). The physical and mechanical properties of PMMA with GO increase considerably without altering sorption, solubility and porosity. Conclusion: GO alone or with PMMA has an acceptable biocompatibility, could contribute to cell proliferation, cell regeneration and improve the physical mechanical properties of PMMA.


Objective: To determine the cytotoxicity and effects of graphene oxide (GO) on cellular proliferation of gingival-fibroblasts, pulpdental cells and human osteoblasts in culture, and to determine the physical, mechanical and biological properties of poly (methyl methacrylate) (PMMA) enriched with GO. Material and Methods: T he G O w as c haracterized with SEM. Cytotoxicity and cell proliferation were determined by the MTT bioassay. The physical-mechanical tests (flexural strength and elastic modulus) were carried out with a universal testing machine. Sorption and solubility were determined by weighing before and after drying and immersion in water. Porosity was evaluated by visual inspection. Data were analyzed with Student's t-test and Tukey's post-hoc ANOVA. Results: The GO has a heterogeneous morphology and a particle size of 66.67±64.76 ?m. GO has a slight to no-cytotoxicity (>50-75% viability) at 1-30 days, and at 24 hours incubation of PMMA with GO significantly stimulates osteoblasts (45±8%, p<0.01). The physical and mechanical properties of PMMA with GO increase considerably without altering sorption, solubility and porosity. Conclusion: GO alone or with PMMA has an acceptable biocompatibility, could contribute to cell proliferation, cell regeneration and improve the physical-mechanical properties of PMMA.


Assuntos
Humanos , Materiais Biocompatíveis , Polimetil Metacrilato/química , Grafite/química , Osteoblastos , Óxidos , Regeneração , Bioensaio , Proliferação de Células , Resistência à Flexão
4.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385695

RESUMO

ABSTRACT: The aim of this study was to systematically review the literature of in vitro studies comparing the mechanical properties of teeth restored after selective caries excavation (SCE) and complete caries excavation (CCE). The PubMed/MEDLINE and EMBASE electronic databases were searched systematically. In vitro studies investigating the mechanical properties of teeth restored after SCE, were independently checked by two authors. Inclusion criteria were: (1) performing SCE (2) mentioning the teeth were later restored, and (3) evaluating mechanical properties of the restored teeth. Meta-analysis was performed with and without discriminating between shallow and deep lesions. From 1,859 potentially eligible studies, 14 were selected for full text analysis and 5 were included in the meta- analysis. Fracture resistance was significantly lower after SCE than after CCE in overall analysis (SMD[95%CI]=-1.62[-3.04,-0.20]) and for deep lesion (SMD[95%CI]=-1.62[-2.62,-0.61]), whereas cuspal deflection at 200 and 400N was significantly higher after SCE than after CCE for discriminated and non- discriminated analyses. Furthermore, for shallow lesions the risk of catastrophic fracture was significantly lower after SCE than CCE (RR[95%CI]=0.58[0.43,0.78]). The included studies presented low and medium risk of bias. The mechanical behavior of restored teeth seems to be affected by the excavation strategy. Although there is a tendency for lower fracture resistance and higher cuspal deflection after SCE, there is a lower risk of catastrophic failure when compared to CCE. However, this conclusion is based on very few in vitro studies.


RESUMEN: El objetivo de este estudio fue revisar sistemáticamente la literatura de estudios in vitro que comparan las propiedades mecánicas de los dientes restaurados después de la excavación selectiva de caries (ESC) y la excavación de caries completa (ECC). Se realizaron búsquedas sistemáticas en las bases de datos electrónicas PubMed / MEDLINE y EMBASE. Los estudios in vitro que investigan las propiedades mecánicas de los dientes restaurados después de la ESC fueron verificados de forma independiente por dos autores. Los criterios de inclusión fueron: (1) realizar ESC (2) mencionar que los dientes fueron posteriormente restaurados y (3) evaluar las propiedades mecánicas de los dientes restaurados. El metanálisis se realizó con y sin discriminación entre lesiones superficiales y profundas. De 1.859 estudios potencialmente elegibles, se seleccionaron 14 para el análisis de texto completo y 5 se incluyeron en el metanálisis. La resistencia a la fractura fue significativamente menor después de ESC que después de CCE en el análisis general (DME [IC del 95 %] = - 1,62 [-3,04, -0,20]) y para la lesión profunda (DME [IC del 95 %] = - 1,62 [-2,62, - 0,61]), mientras que la deflexión de las cúspides a 200 y 400 N fue significativamente mayor después de ESC que después de CCE para análisis discriminados y no discriminados. Además, para las lesiones superficiales, el riesgo de fractura catastrófica fue significativamente menor después de ESC que de CCE (RR [IC 95 %] = 0,58 [0,43,0,78]). Los estudios incluidos presentaron riesgo de sesgo bajo y medio. El comportamiento mecánico de los dientes restaurados parece verse afectado por la estrategia de excavación. Aunque existe una tendencia a una menor resistencia a la fractura y una mayor deflexión de la cúspide después de la ESC, existe un menor riesgo de falla catastrófica en comparación con la CCE. Sin embargo, esta conclusión se basa en muy pocos estudios in vitro.

5.
Rev. Fac. Odontol. Univ. Antioq ; 32(2): 75-81, July-Dec. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1149613

RESUMO

Abstract Introduction: yttrium-stabilized zirconium dioxide (zirconia) has been used to manufacture fixed partial prosthesis due to its high flexural strength. However, there are no available studies comparing the effect of two sintering techniques on flexural strength. This study aims to compare the flexural strength of zirconia sheets manufactured with two sintering techniques. Method: for this in vitro study, three zirconia disks were used (Upcera: Super Translucent (ST): 1200 MPa, Multi-Layer (ML): 600 MPa and High Translucent (HT): 1200 MPa), using an Isomet® cutter to prepare 60 sheets 2 mm thick, 5 mm wide and 37 mm long. These sheets were randomly distributed into two groups of 30: the first group was sintered for 8 hours at 1,530°C and the second group was subjected to fast sintering for 3 hours at 1,530°C. The flexural strength in Newton was measured on an Instrom® 3366 Universal Testing Machine. The results were converted from N to MPa and compared by ANOVA and t test. Results: no statistically significant difference was found in the flexural strength of the two groups (p>0,05). Conclusion: the two compared sintering procedures do not affect the flexural strength of zirconia sheets.


Resumen Introducción: las restauraciones de dióxido de zirconio estabilizadas con ytrio para prótesis parciales fijas e implantosoportadas se han utilizado por su alta resistencia flexional. En la revisión bibliográfica no se encontraron estudios que comparen la resistencia flexional del dióxido de zirconio con 2 tiempos de sinterización diferentes. El objetivo del presente estudio consistió en comparar la resistencia flexional de láminas elaboradas en 3 tipos de dióxido de zirconio con 2 tiempos de sinterización. Método: en este estudio in vitro, se recolectaron 3 discos de dióxido de zirconio (Upcera: Súper translúcido (ST): 1200 MPa, Multicapa (ML): 600 MPa y Alta translucidez (HT): 1200 MPa), y en un aparato de corte Isomet® se recortaron 60 láminas de 2 mm de espesor, ancho de 5 mm y longitud de 37 mm. Estas láminas se distribuyeron aleatoriamente en dos grupos de 30: el grupo uno se sinterizó por 8 horas a 1.530°C y el otro grupo se sometió a sinterización rápida por 3 horas a 1.530°C. La resistencia flexional se midió en una máquina universal Instrom® 3366. Los resultados fueron convertidos de N a MPa y se compararon mediante análisis de varianza y prueba t. Resultados: no hubo diferencia estadísticamente significativa al comparar la resistencia flexional después de dos tiempos de sinterización diferentes (p>0,05). Conclusiones: no se presentaron diferencias significativas en la resistencia flexional del dióxido de zirconio al comparar los promedios obtenidos con dos técnicas de tiempo de sinterización diferente.


Assuntos
Resistência à Flexão
6.
Actual. osteol ; 12(3): 169-179, 2016. graf, tab
Artigo em Inglês | LILACS, UNISALUD, BINACIS | ID: biblio-1370677

RESUMO

Pre-clinical data have shown that tissue level effects stemming from bisphosphonateinduced suppression of bone remodeling can result in bone that is stronger yet more brittle. Raloxifene has been shown to reduce bone brittleness through non-cellular mechanisms. The goal of this work was to test the hypothesis that raloxifene can reverse the bone brittleness resulting from bisphosphonate treatment. Dog and mouse bone from multiple bisphosphonate dosing experiments were soaked in raloxifene and then assessed for mechanical properties. Mice treated with zoledronate in vivo had lower post-yield mechanical properties compared to controls. Raloxifene soaking had significant positive effects on select mechanical properties of bones from both vehicle and zoledronate treated mice. Although the effects were blunted in zoledronate bones relative to vehicle, the soaking was sufficient to normalize properties to control levels. Additional studies showed that raloxifene-soaked bones had a significant positive effect on cycles to failure (+114%) compared to control-soaked mouse bone. Finally, raloxifene soaking significantly improved select properties of ribs from dogs treated for 3 years with alendronate. These data show that ex vivo soaking in raloxifene can act through non-cellular mechanisms to enhance mechanical properties of bone previously treated with bisphosphonate. We also document that the positive effects of raloxifene soaking extend to enhancing fatigue properties of bone. (AU)


Los datos preclínicos han demostrado que los efectos a nivel de tejido que se derivan de la supresión del remodelado óseo inducida por bifosfonatos puede dar como resultado un hueso que es más fuerte pero más frágil. Está comprobado que el raloxifeno reduce la fragilidad ósea a través de mecanismos no celulares. El objetivo de este trabajo fue probar la hipótesis de que el raloxifeno puede revertir la fragilidad ósea resultante del tratamiento con bifosfonatos. Se emplearon huesos de perro y ratón de múltiples experimentos con diferentes dosis de bifosfonatos los cuales fueron sumergidos en raloxifeno y luego se evaluaron sus propiedades mecánicas. Ratones tratados con zoledronato in vivo mostraron propiedades mecánicas post-rendimiento más bajas en comparación con los controles. Luego de sumergirlos en raloxifeno se observaron efectos positivos significativos en algunas propiedades biomecánicas tanto en los huesos de ratones tratados con vehículo como con zoledronato. Aunque los efectos se atenuaron en los huesos tratados con zoledronato en relación con los tratados con vehículo, el raloxifeno fue suficiente para normalizar las propiedades a niveles basales. Estudios adicionales mostraron que los huesos sumergidos en raloxifeno tuvieron un efecto positivo significativo en los ciclos de fractura (+ 114%) en comparación con los huesos de ratón sumergido en vehículo. Finalmente, el raloxifeno mejoró significativamente las propiedades de costillas de perros tratados durante 3 años con alendronato. Estos datos muestran que la inclusión ex vivo en raloxifeno puede actuar a través de mecanismos no celulares para mejorar las propiedades mecánicas de huesos previamente tratado con bifosfonatos. También documentamos que los efectos positivos del raloxifeno mejoran las propiedades de fatiga del hueso. (AU)


Assuntos
Animais , Masculino , Feminino , Cães , Camundongos , Osteogênese Imperfeita/induzido quimicamente , Osteogênese Imperfeita/tratamento farmacológico , Remodelação Óssea/efeitos dos fármacos , Cloridrato de Raloxifeno/administração & dosagem , Difosfonatos/efeitos adversos , Fenômenos Biomecânicos/efeitos dos fármacos , Osso e Ossos/fisiopatologia , Alendronato/efeitos adversos , Cloridrato de Raloxifeno/farmacologia , Modelos Animais de Doenças , Fadiga/tratamento farmacológico , Ácido Zoledrônico/efeitos adversos
7.
Rev. bras. ciênc. esporte ; 35(3): 547-559, jul-set. 2013. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-699255

RESUMO

O efeito do treinamento aeróbio ainda apresenta resultados conflitantes com relação às respostas biomecânicas apresentadas pelo tendão após um período de treinamento aeróbio moderado, como a corrida. Este estudo tem como objetivo avaliar o efeito de um protocolo de corrida de intensidade moderada em esteira sobre as propriedades mecânicas dos tendões do calcâneo de ratos. Para o ensaio mecânico os tendões foram tracionados até o ponto de fracasso do espécime. O treinamento aeróbiode intensidade moderada em ratos não causa alterações nas propriedades biomecânicas do tendão de calcâneo, desta forma, parece não representar risco podendo ser eficaz por não levar o tendão do Calcâneo ao estresse e a fadiga mecânica.


The effect of aerobic training has presented conflicting results regarding the biomechanical responses submitted by the tendon after a period of moderate aerobic training such as running. This study aims to evaluate the effect of a protocol running on a treadmill at moderate intensity on the mechanical properties of the Achilles tendons of rats. For mechanical test the tendons were pulled to the point of failure of the specimen. The moderate-intensity aerobic training in rats does not changes in the biomechanical properties of the Achilles tendon, thus, does not seem to pose a risk can be effective for not taking the Achilles tendon to mechanical stress and fatigue.


El efecto de entrenamiento aerobio ha presentado resultados contradictorios respecto a las respuestas biomecánicas presentado por el tendón después de un período de entrenamiento aerobio moderado, como correr. Este estudio pretende evaluar el efecto de un protocolo de correr en una cinta a una intensidad moderada en las propiedades mecánicas de los tendones de Aquiles de las ratas. Para pruebas mecánicas de los tendones se retiraron hasta el punto de fracaso de la muestra. El entrenamiento aerobio de intensidad moderada en las ratas no provoca cambios en las propiedades biomecánicas del tendón de Aquiles, por lo tanto, no parece representar un riesgo puede ser eficaz para no tomar el tendón de Aquiles a la tensión mecánica y la fatiga.

8.
Rev. ing. bioméd ; 1(2): 22-29, graf
Artigo em Espanhol | LILACS | ID: lil-773315

RESUMO

En un modelo con características geométricas y un comportamiento mecánico de la pared arterial generalizado para aneurismas periféricos, se realiza una modelación por elementos finitos (MEF) del efecto de la presión arterial y del espesor de la pared arterial en el saco de un aneurisma. Se analizan los esfuerzos de Von Misses, los esfuerzos tensores transversales y el desplazamiento en el saco del aneurisma. Se encuentra que el lugar más propenso a la ruptura para esta geometría de aneurismas es la región circundante a la arteria eferente y opuesta al flujo aferente. Se propone un proceso para realizar MEF en cualquier geometría de aneurisma y condiciones de presión, para analizar el riesgo y el lugar más probable de la ruptura.


Considering a model with generalized geometry and mechanical properties of the arterial wall for the peripheral vasculature aneurisms, a finite element modeling (FEM) is developed for analyzing the effects of arterial blood pressure and the arterial wall thickness in the aneurismal sac. The von Misses stresses, the transversal tensor stresses and the displacement in the aneurismal sac wall are analyzed. The possible site of rupture for this aneurism geometry is found surrounding the efferent artery and opposed to the flow inlet. A method for applying FEM to any aneurism geometry and blood pressure conditions is proposed for analyzing the risk of rupture and possible rupture site.

9.
Rev. bras. med. esporte ; 13(1): 55-59, jan.-fev. 2007. ilus, graf
Artigo em Português | LILACS | ID: lil-461054

RESUMO

A estimulação elétrica neuromuscular (EENM) é um importante recurso utilizado em medicina esportiva para acelerar processos de recuperação. O objetivo deste estudo foi analisar os efeitos da EENM durante a imobilização do músculo gastrocnêmio, em posições de alongamento (LP) e encurtamento (SP). Para tanto, 60 ratas fêmeas jovens Wistar foram distribuídas em seis grupos e acompanhadas durante sete dias: controle (C), eletroestimuladas (EE), imobilizadas em encurtamento (ISP), imobilizadas em alongamento (ILP), imobilizadas em encurtamento e eletroestimuladas (ISP + EE) e imobilizadas em alongamento e eletroestimuladas (ILP + EE). Para a imobilização, o membro posterior direito foi envolvido por uma malha tubular e ataduras de algodão juntamente à atadura gessada. A EENM foi utilizada com freqüência de 50Hz, 10 minutos por dia, totalizando 20 contrações em cada sessão. Após sete dias os animais foram submetidos a eutanásia e os músculos gastrocnêmios retirados para a realização do ensaio mecânico de tração em uma máquina universal de ensaios (EMIC®). A partir dos gráficos carga versus alongamento, foram calculadas as seguintes propriedades mecânicas: alongamento no limite de proporcionalidade (ALP), carga no limite de proporcionalidade (CLP) e rigidez. As imobilizações SP e LP promoveram reduções significativas (p < 0,05) nas propriedades de ALP e CLP, sendo mais acentuada no grupo ISP. Quando utilizada a EENM, houve acréscimo significativo (p < 0,05) dessas propriedades somente no grupo ISP. Já em relação à rigidez, foi observada redução significativa (p < 0,05) somente do grupo C para o grupo ISP. Quando utilizada a EENM, a rigidez do grupo ILP + EE foi significativamente (p < 0,05) maior e mais próxima do grupo C que a do grupo ISP + EE. Neste modelo experimental, a imobilização dos músculos em alongamento atrasou o processo de atrofia, e a estimulação elétrica, realizada durante a imobilização, contribuiu para a manutenção das propriedades...


The neuromuscular electric stimulation (NMES) is an important tool used in sports medicine to accelerate the recovery process. The objective of this study was to analyze the effects of NMES during immobilization of the gastrocnemius muscle, in lengthened (LP) and shortened positions (SP). Sixty young female Wistar rats were distributed into six groups and followed for 7 days: control (C); electric stimulation (ES); immobilized in shortening (ISP); immobilized in lengthening (ILP); immobilized in shortening and electric stimulation (ISP + ES) and immobilized in lengthening and electric stimulation (ILP + ES). For the immobilization, a tubular mesh and cotton rolls together with the plaster were wrapped around the rat's right posterior paw. NMES in a frequency of 50 Hz was used 10 minutes a day, totaling 20 contractions in each session. After 7 days the animals were sacrificed and their gastrocnemius muscles of the right paw were submitted to a mechanical test of traction in a universal test machine (EMIC®). From the load versus elongation curves the following mechanical properties were obtained: elongation in the yield limit (EPL), load in the yield limit (LPL) and stiffness. The SP and LP immobilizations promoted significant reductions (p < 0.05) in the EPL and LPL properties, being more remarkable in the ISP group. When the NMES was used, there was significant increase (p < 0.05) of these properties only in the ISP group. As for stiffness, significant reduction was observed (p < 0.05) only of the C group for the ISP group. When the NMES was used, the stiffness of the ILP + EE group was significantly (p < 0.05) higher and closer to the C group than of the ISP + EE group. We conclude that in this experimental model the immobilization of the muscles in the lengthened position delayed the atrophy process and the electric stimulation during the immobilization contributed to the maintenance of the mechanical properties during the immobilization...


La estimulación eléctrica neuromuscular (EENM) es un importante recurso utilizado en medicina deportiva para acelerar procesos de recuperación. El objetivo de este estudio ha sido analizar los efectos de la EENM durante la inmovilización del músculo gastrocnemio, en posiciones de alongamiento (LP) y contracción (SP). Para tal fin, 60 ratones hembras jóvenes Wistar fueron distribuidas en seis grupos y monitoreadas durante 7 días: control (C), electro estimuladas (EE), inmovilizadas en contracción (ISP), inmovilizadas en alongamiento (ILP), inmovilizadas en contracción y electro estimuladas (ISP + EE) e inmovilizadas en alongamiento y electro estimuladas (ILP + EE). Para la inmovilización, el miembro posterior derecho fue envuelto por una malla tubular y vendas de algodón en conjunto con vendas de escayola. La EENM fue utilizada con una frecuencia de 50 Hz, 10 minutos por día, totalizando 20 contracciones en cada sesión. Después de 7 días los animales fueron sometidos a eutanasia y los músculos gastrocnemios fueron retirados para la realización del ensayo mecánico de tracción en una máquina universal de ensayos (EMIC®). A partir de los gráficos carga versus alongamiento se calculó las siguientes propiedades mecánicas: alongamiento en el límite de proporcionalidad (ALP), carga en el límite de proporcionalidad (CLP) y rigidez. Las inmovilizaciones SP y LP dieron reducciones significativas (p < 0,05) en las propiedades de ALP y CLP, siendo más acentuada en el grupo ISP. Cuando utilizamos la EENM, hubo un crecimiento significativo (p < 0,05) de estas propiedades solamente en el grupo ISP. Por otro lado, en relación a la rigidez, se observó una reducción significativa (p < 0,05) solamente del grupo C respecto al grupo ISP. También se observó que al usarse EENM, la rigidez del grupo ILP + EE fue significativamente (p < 0,05) mayor y más próxima del grupo C que la del grupo ISP + EE. En este modelo experimental, la inmovilización de los músculos...


Assuntos
Animais , Ratos , Atrofia Muscular/terapia , Fenômenos Biomecânicos , Terapia por Estimulação Elétrica , Imobilização , Ratos Wistar , Resistência à Tração
10.
Acta cient. venez ; 54(1): 18-27, 2003. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: lil-351687

RESUMO

Se estudió la degradación hidrolítica in vitro de suturas de Poliglactin 910 utilizando un buffer de fosfato , pH= 7,4, a 37 °C. La degradación fue evaluada a través de la perdida en peso, cambio en las propiedades térmicas, morfología y propiedades mecánicas de las suturas sometidas a hidrólisis. Después de 10 semanas, los resultados obtenidos de la pérdida en peso y pH sugieren la difusión de especies de bajo peso molecular al medio de reacción como consecuencia del ataque hidrolítico a los grupos éster en el polímero. La disminución de las propiedades mecánicas, tanto el esfuerzo de ruptura como el modulo, junto con los resultados anteriores sugieren que el proceso de escisión de cadenas procede en dos etapas: la primera ocurre en las zonas amorfas y la segunda en las zonas cristalinas. El estudio de la morfología correspondiente a la superf icie de las sutura revela un mecanismo de degradación heterogéneo por capas.


The hydrolytic degradation of bioabsorbable Poliglactin 910 was studied in a phosphate buffer solution, pH= 7,4, at 37 °C. The degradation was evaluated by analyzing the changes in weight loss, pH, DSC, mechanical properties and morphological changes. After 10 weeks, the weight loss and pH changes suggested diffusion of low molecular weight chain segments into the reaction medium as a consequence of the breaking of ester bonds in the material. Breaking stress and Young Modulus decrease, indicating that chain scission proceeded in two steps: the first ocurring in the amorphous regions within the intermicrofibrillar space; the second in the crystalline regions. Surface morphological changes suggest a heterogeneous degradation mechanism by layers.


Assuntos
Poliglactina 910 , Materiais Biocompatíveis , Biodegradação Ambiental , Teste de Materiais , Microscopia Eletrônica de Varredura , Concentração de Íons de Hidrogênio , Hidrólise
11.
Rev. Estomat ; 9(2): 30-38, sept. 2001. tab, ilus
Artigo em Espanhol | LILACS | ID: lil-569565

RESUMO

Usualmente cuando leemos las instrucciones de manejo de un material odontológico sólo analizamos los pasos para su manipulación y colocación en la boca y pasamos de largo la descripción de sus propiedades mecánicas. Esta situación obedece a que los términos y medidas que se emplean son poco familiares para los odontólogos y los textos de biomateriales odontológicos son bastante complejos cuando explican las propiedades mecánicas. En consecuencia, perdemos la posibilidad de evaluar críticamente el comportamiento mecánico de muchos materiales, quedando como única posibilidad la evaluación de sus comportamientos clínicos. El objetivo de esta revisión es explicar de una forma sencilla y precisa conceptos básicos de ingeniería mecánica aplicados a la odontología. De esta manera aumentamos nuestra capacidad de evaluar nuevos materiales dentales, ya que podremos interpretar datos y valores de sus propiedades físicas, con lo cual estaremos en capacidad de entender parte de su interacción con las estructuras del sistema masticatorio. Se espera también que con estas ideas sea posible comprender los resultados de estudios recientes de fotoelasticidad (Toshifumi, 2000), estudios de elementos finitos (Varón et al, 2000), estudios de resistencia compresiva de tejido óseo fresco según contenido de Fluor (Mena 1993) y otros estudios aplicados a la biomecánica dental.


Usually when we read about handling instructions of some dental materials, We are concemed about the manipulation and how it should be placed in the mouth. Some terms and measures given in the dental material books are difficult to understand. Therefore, we lost criteria to evaluate on mechanic properties of many dental materials, we are only familiarized with the clinical behavior of them. The purpose of this literature review is to explain in a simple and precise way the importance of increasing our knowledge about this topic, and giving us the opportunity of taking a correct decision to choosing a restorative dental material in benefit of our patients oral health. Schematic representations are used to explain terms like; stress, deformation, elastic limit, yield strength, ultimate strength, poisson's ratio, ductility, elongation, resilience and toughness.


Assuntos
Aparelhos Ortodônticos , Fenômenos Biomecânicos , Materiais Dentários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...